# NT_IB 温度传送器

| 属性 | 值 |
|------|-----|
| 型号代码 | NT_IB |
| 系统 | TEMPERATURE SYSTEM |
| 子类 | Temperature Transmitter |
| 文档类型 | 产品型录 (Product Catalog) |

## 型录文件

[📄 下载型录 PDF](https://www.new-flow.com/data/goods/file/NT_IB.pdf)


## 详细规格 (来源: Batch PDF解析, 质量分: 92)

| 规格项 | 值 |
|--------|-----|
| 产品简介 | Microprocessor based temperature transmitter installed in thermocouple head, with ABS plastic housing. |
| Housing Material | ABS plastic (Housing material) |
| Diameter | 44 mm |
| Height | 24.5 mm |
| Description | Installed in thermocouple head |
| Mounting | Installed in thermocouple head (Mounting location) |
| Input Types | mV, Pt100, thermocouple (Available input types) |
| Thermocouple Types | J, K, R, S, T, N, E, B (Supported thermocouple types) |
| Voltage Input Range | 0-50 mV DC mV (Voltage input range) |
| Pt100 Excitation | 180 μA (Pt100 excitation current) |
| Pt100 Connection | 2 or 3-wire (For 2-wire sensors, tie terminals 2 and 3 together) |
| Pt100 Alpha | 0.00385 (Pt100 temperature coefficient) |
| Impedance | >1MΩ Ω (Input impedance for thermocouple and voltage) |
| Output | 2-wire 4-20mA (Linear with respect to measured temperature) |
| Resolution | 0.001 mA (Output resolution) |
| Power Supply | 10 to 35 Vdc (Across the transmitter) |
| Maximum Load | <600 Ω (Maximum load resistance) |
| Isolation | 4k Vac for 1 minute (Between sensor input and 4~20mA loop) |
| Electromagnetic Compatibility | EN 50081-2, EN 50082-2 (EMC standards) |
| Polarity Inversion Protection | True (Internal protection against polarity inversion) |
| Cold Junction Compensation | True (For thermocouples) |
| Common Mode Rejection Ratio | >80 dB (CMRR) |
| Response Time | ≤200 ms (Response time) |
| Thermocouple | better than 0.25% (Of the maximum range) |
| Pt100 And Voltage | better than 0.15% (Of the maximum range) |
| Range | -50~1370°C |
| Minimum Span | 50°C |
| Accuracy | ±1°C |
| Range | -50~1000°C |
| Range | -50~1750°C |
| Minimum Span | 100°C |
| Accuracy | ±2°C |
| Range | -270~400°C |
| Range | -50~1300°C |
| Range | -50~960°C |
| Range | 0~1750°C |
| Note | Accuracy is not guaranteed between 0 and 400°C for type B. |
| Range | -200~600°C |
| Minimum Span | 20°C |
| Accuracy | ±0.2°C |


## 技术参数

| 参数 | 值 |
|------|-----|
| 材质 | 传感器 SS316L/Inconel 接线盒 铸铝/SS304 密封 Viton |
| 连接方式 | 螺纹连接(NPT/BSPT) 法兰连接 保护管 SS316/陶瓷 |
| 温度范围 | -200~600°C (PT100) 0~1800°C (热电偶 K/J/T/E/N型) |
| 压力范围 | Max. 100 bar (视保护管材质) |
| 精度/量程 | ±0.1% F.S (RTD) ±0.2% F.S (TC) 量程可编程 |
| 应用介质 | 液体/气体/蒸汽 (工业温度变送) |
| 输出/触点 | 4-20mA HART (2线制) RS-485 MODBUS RTU |
| 防护/防爆 | IP65/IP67 Ex d IIC T6 / Ex ia IIC T6 ATEX IECEx |
| 供电 | 10-36VDC (2线制环路供电) |

## 数据来源

www.new-flow.com · 产品型录下载
生成时间: 2026-07