| - Dial:ø4”, ø6” available
- Measuring Range: 0~(-1) kg/cm² ; 1~400 kg/cm² available
- Material:Bourdon tube SS316; Wetted parts SS316
- Housing:SS304; option SS316 o
- Protection Class:IP66
- Lens:Safety glass
- Blow-out:Back ø25mm (1”)
- Pressure Limited:Over range protected 130% of full scale range
- Accuracy:Gauge indication ±1.0% F.S
- Span Range & Zero Adjustable
- Process Connection:½”NPT male Bottom or Back connection; option with adaptor available
- Electronic Connection:DIN43650, Universal plug connector; option with adaptor available
- Switch Form:One setting point: SPDT x 1 ; Two setting points: SPDT x 2 available
(Negative pressure only"one setting point"available.) - Set Point:Full scale range available
- Switch Dead Band:Please check theRange Selection Tablein catalogue for SPDT x 1 & SPDT x 2
- Switch Data: AC Load 250VAC max. ; DC Load 28 VDC max.
|