The LG-25 hydrostatic level probe is designed to measure liquid levels in tanks,
abyssal wells or piezometers.
- Any Measurement Range:1~500 mH2O (we recommend the standard ranges 4, 10, 20, 50, 100mH²O)
- Long Term Stability:0.1% or 1 cm H2O for 1 year
- Hysteresis, Repeatability:0.05%
- Thermal Compensation Range:0~25°C standard; -10~70°C special version available
- Medium Temperature Limit:-25~50°C for range > 20 mH2O, -25~75°C for range ≤ 20 mH2O
- Output Signal:4~20mA, 2-wires transmission;
Special Version 0~10V, 3-wires transmission - Power Supply:10~30VDC
- Error Due to Supply Voltage Changes:0.005%/V
- Protection Rating of Casing:IP68
- Material of Casing and Diaphragm:SS316L
- Cable Shielding:POLYURETHANE